Fujitsu specializes in ductless systems built on inverter technology, and the Fujitsu equipment we service in Mountain View and Los Altos is ductless: mini-splits and multi-zone systems with one outdoor unit feeding several rooms. The calls fall into three groups. An outdoor board fault stops the whole system, a drain problem puts water on a wall, and remote control trouble makes a working unit look dead. The first question we ask, and the one that sorts most of them, is simple: is one room affected, or all of them?
Fujitsu equipment we work on
- Ductless mini-splits: a single wall-mounted indoor unit with its own outdoor unit, typical for one room or an addition.
- Multi-zone systems: one outdoor unit serving several indoor units, each with its own remote or controller.
Both heat and cool, and both use an inverter compressor that ramps up and down rather than cycling on and off. A unit that runs quietly for hours is usually working as designed.
One room or every room?
On a multi-zone system the answer splits the diagnosis in two:
- Every indoor unit stops, or none of them heat or cool. The shared parts are the suspects: power to the outdoor unit, the outdoor board, the outdoor fan motor, the compressor or the refrigerant charge.
- Only one indoor unit misbehaves. The problem lives with that unit: its sensor, its fan motor, its board, its drain or its communication wiring to the outdoor unit.
Outdoor board failures
The outdoor board runs the compressor and fan, and it talks to every indoor unit. When it fails, the indoor units usually show a fault by flashing their indicator lamps in a pattern. Note which lamps flash and how many times before turning the power off; cutting power can clear it.
Boards fail from power surges, heat and moisture, and sometimes from insects nesting in the outdoor unit’s electrical compartment. But a failing fan motor, a shorted compressor winding or a broken communication wire can also produce a board fault, and a new board installed on top of them fails again. So we check the supply voltage, the communication signal between the units, the fan motor, the sensors and the compressor windings first. The board is replaced when everything around it tests good, and you know the price and how long the part takes to arrive before we order it.
Drain issues
Every Fujitsu indoor unit pulls water out of the air when it cools, and that water has to leave the house. On a wall unit it usually drains by gravity through a small hose that runs out with the refrigerant lines; where gravity cannot do the job, a small condensate pump lifts it. Leaks come from:
- algae and dust clogging the drain pan or hose;
- a hose that has sagged, kinked or lost its slope;
- a condensate pump or its float that has stopped working;
- a dirty filter or coil that lets ice form and then melt all at once.
We clear and flush the drain, correct the slope, test the pump and clean the coil and blower wheel when they are part of the problem.
Remote control problems
Many “the remote stopped working” calls on a multi-zone Fujitsu are a mode conflict: the outdoor unit can heat or cool, not both, so a room set to the opposite mode waits. Fresh batteries, the right mode and a clear line between the remote and the indoor unit fix most of the rest. If a unit still ignores a working remote, we test its receiver and board; a wired wall controller gets its wiring checked as well.
A good fit for room additions
Ductless systems are a common answer for an addition, a converted garage or a remodeled room that the existing ducts never reached. If you are adding a room or replacing a failed unit, see AC installation; if one room in the house is always too warm or too cool, our page on uneven temperatures helps you decide whether ducts or a ductless unit is the better fix.
What to have ready, parts and warranty
Each indoor unit and the outdoor unit carry their own label with the model and serial number: on the side of the indoor unit or under its front cover, and on the side of the outdoor unit. On a multi-zone system, photograph all of them, plus the lamp pattern. Fujitsu boards, sensors and motors are model-specific. Manufacturer parts warranties depend on the model, the install date and registration; when a covered part fails, we help you with the claim. Our labor warranty is written on your invoice.
Local notes
In Mountain View, Eichler homes with glass walls and no ducts often rely on ductless units, and rooms facing the afternoon sun keep them busy from July to September, which is when clogged drains show up. In Los Altos ranch homes with forced-air heat, a ductless unit is one way to condition an addition or a remodeled room the ducts do not reach. Rinsing the washable filters regularly and a yearly cleaning of the coil, blower wheel and drain prevent most of the leaks above. For Mountain View, see also our Fujitsu repair in Mountain View page and our heat pump services.