Heil HVAC Repair in Mountain View & Los Altos

A Heil system that stops cooling or heating usually has one failed part, not a failed system. The work is finding which one, and on Heil equipment that often means sorting out a control board, the compressor's start circuit or a coil leak.

  • Same-day appointments
  • Price before work starts
  • 24/7 phone support

Heil HVAC repair in Mountain View and Los Altos usually involves a Heil central air conditioner or heat pump outside and a Heil furnace or air handler inside. When the system quits, the cause is often an electrical part around the compressor, a control board shutting things down because of a fault somewhere else, or refrigerant escaping from a coil. We test first, explain what we found in plain English and give you the price before any work starts. Peninsula HVAC Repair is an independent service provider, not affiliated with Heil.

Heil equipment we work on

Heil builds mid-range heating and cooling equipment, and we service all four main types:

  • Central air conditioners. The outdoor unit holds the compressor, the condenser coil and the fan; an indoor coil sits on the furnace or air handler.
  • Heat pumps. The same kind of outdoor unit, with a reversing valve and a defrost control so it can heat in winter.
  • Gas furnaces. Heat, plus the blower that also moves the air when the AC runs.
  • Air handlers. The indoor blower and coil for a heat pump system, often with electric heat for backup.

A heat pump blowing cool air in winter and a furnace that will not light are different diagnoses; see heat pump services and furnace repair.

Control board problems: the board is often the messenger

A modern Heil furnace is run by a control board with a status light that blinks a code when something is wrong. A board that seems dead, or keeps shutting the system down, is often reacting correctly to a fault elsewhere: a pressure switch that does not close, a limit switch opened by a clogged filter, or a 24-volt circuit with no power because the transformer has failed. So we read the code, then test what the board is waiting for: incoming power, the transformer output, the board’s fuse, the thermostat signals and the safety switches. Only a board that receives the right inputs and still does not respond gets replaced. Swapping the board first is how owners end up paying for two.

Compressor issues: is it the compressor, or what starts it?

The compressor is the most expensive part of the outdoor unit, and it often gets blamed for faults in the small parts around it.

What you noticeWhat it can beHow we tell
Outdoor unit hums, fan and compressor do not runWeak run capacitor, failed contactor or a stuck compressorCapacitor tested against its rating, voltage at the contactor, amp draw at start
Compressor starts, then shuts off after a few minutesOverheating from a dirty condenser coil or a failed fan motorCoil and fan check, running temperatures and amps
Fan runs but the compressor stays silentInternal overload open after overheating, wiring or capacitorLet it cool, then test the circuit and the windings
Breaker trips the moment the AC startsShorted compressor winding or a wiring faultWinding and ground tests with the power off

A hard-start kit can help a healthy compressor that struggles to start, but it does not fix a shorted winding. If the compressor itself has failed, you get the repair price and an honest comparison with replacement before you decide; our AC installation page covers what a new system involves.

Coil leaks

A coil leak rarely announces itself. The system takes a little longer to cool each week until a hot afternoon shows it cannot keep up, or frost appears on the larger copper line. Adding refrigerant without finding the leak only buys time. Our EPA-certified technicians search the indoor coil, the outdoor coil, the valves and the joints, then explain the options: repairing a joint or valve, replacing the coil or, if the system is old, weighing a new one. See the refrigerant leak guide and AC blowing warm air.

Have this ready when you call

  • A photo of the data plate on the outdoor unit (model and serial number) and of the label inside the furnace or air handler door.
  • The blink code, counted before anyone switches the power off.
  • What the system did just before it stopped: a hum, a click, a tripped breaker, ice on the lines.
  • Roughly when it was installed, and whether anyone has added refrigerant before.

Parts and warranty

Capacitors, contactors and fuses are standard parts. Control boards, motors and coils have to match the model, the serial number and the refrigerant the system uses, and we confirm the right part is available before quoting. Parts warranties come from the manufacturer; whether a part is still covered usually depends on the install date and on whether the equipment was registered. Send us the model, serial number and install date and we help you with the claim. Our labor warranty is written on your invoice.

Local notes

Mountain View and Los Altos sit inland, and summer afternoons are often hot from July to September. That is when a tired capacitor, or a compressor working against a dirty condenser coil, finally quits. Heating runs mostly from November to March, and the first cold night shows which furnace boards and safety switches have a problem. In many Los Altos ranch homes the ducts run through the attic or crawlspace, so if one room stays warm after a repair, duct repair may be the next question. For visits in Mountain View, see Heil service in Mountain View.

Frequently asked

My Heil outdoor unit hums but nothing spins. Is the compressor dead?

Not necessarily. A weak run capacitor or a failed contactor causes the same hum and is a much smaller repair. Switch the system off at the thermostat and call; running it like that can overheat the compressor.

What does the blinking light on my Heil furnace mean?

It is a status code from the control board, and the chart is usually printed inside the furnace door. Count the flashes before you turn the power off, because a power cycle clears it. The code names a circuit to test, not a part to buy.

Can a leaking Heil coil be repaired?

Sometimes. A leak at an accessible joint or valve can often be repaired; a leak inside the coil usually means a new coil or, on an older system, a talk about replacement. We find the leak before quoting either.