Direct answer: Ice on the indoor coil or the copper refrigerant lines means the coil is running below freezing. The most common causes are a dirty filter, closed or blocked vents, a weak blower, a dirty indoor coil and low refrigerant from a leak; running the AC through cool nights can add to it. Turn cooling off, run the fan to thaw the ice, replace the filter and open the vents. If the ice comes back after you restart, or the filter was clean to begin with, call for a diagnosis.
Why a coil freezes
The indoor (evaporator) coil normally runs cold but above freezing, because warm house air keeps flowing across it. Take away airflow and the coil keeps getting colder until moisture from the air freezes on the fins. The ice blocks even more air, so it grows. Low refrigerant does the same from the other side: lower pressure in the coil means a lower coil temperature.
| Cause | Clue |
|---|---|
| Dirty filter | Grey, matted filter; weak air at every vent |
| Closed or blocked vents and returns | Many registers shut, furniture over a return grille |
| Blower problem | Weak airflow even with a new filter; motor runs slow or hums |
| Dirty indoor coil | Low airflow with a clean filter, often after years without maintenance |
| Low refrigerant from a leak | Filter and airflow fine but ice still forms; sometimes hissing or oily spots on fittings |
| Running in cool weather | Ice after the AC runs through a cool night at a low setting |
| Restriction in the refrigerant circuit | No visible clue; found by measuring pressures and temperatures |
How to thaw a frozen coil safely
- Set the thermostat to Off and the fan to On. Moving air melts the ice faster.
- Replace the filter now if it is dirty, and open closed vents.
- Put towels around the indoor unit. Melting ice makes a lot of water, and a drain that is clogged or iced over can overflow the pan.
- Wait two to three hours, longer if the coil was a solid block. The copper line at the indoor unit should be free of frost before you restart.
- Do not chip, scrape or melt the ice with a heat gun. The fins and tubing are thin, and a punctured coil means a leak.
- Restart cooling and check the larger copper line again over the next hour. Frost creeping back means the cause is still there.
Running cooling on a frozen coil does nothing for comfort and can send liquid refrigerant back to the compressor.
When to stop and call
Call if the ice returns after thawing, the filter was not dirty in the first place, it keeps happening, you suspect a leak, the system makes strange sounds, or water has come through a ceiling or wall. These point to a blower, coil or refrigerant problem that a filter change will not solve.
What a technician checks
- Airflow: filter, blower motor and speed, duct static pressure and the condition of the indoor coil.
- Refrigerant: pressures, superheat and subcooling, measured once airflow is confirmed. A low charge gets a leak search before any refrigerant goes in, because refrigerant is not used up.
- Metering device and lines: a restriction can freeze a coil even with the right charge.
- Drain: condensate pan, line and float switch, since a freeze and thaw often floods them.
You hear what caused the ice and what the fix involves, with the price before work starts. See AC repair, refrigerant leak if a leak is found, and poor airflow for airflow causes. Regular AC maintenance, with coil and filter checks, prevents most freeze-ups.
Heat pumps in winter
Frost on a heat pump’s outdoor unit on a cold morning is normal. The unit runs a defrost cycle to clear it, sometimes with a cloud of steam. An outdoor unit that stays encased in thick ice is not normal; see heat pump services.
A note for Mountain View and Los Altos
Summer nights here cool off even after hot inland afternoons. If the AC is set low and runs through a cool night, that adds to the freezing risk, especially with a borderline filter or charge, so raise the setting at night or let the house cool naturally. If the indoor unit sits in an attic, as in many homes with attic ductwork, meltwater that overflows the pan can show up as a stain on the ceiling below. Ductless mini-splits in Mountain View Eichlers can ice up too when their washable filters clog. Local pages: Mountain View and Los Altos.