Direct answer: If your furnace is not heating the house, first check the thermostat mode, setpoint and batteries, the air filter, the breaker and the furnace power switch, and whether gas is reaching the house. If the furnace starts and then stops, blows cold air, flashes an error light, smells like gas or sets off a carbon monoxide alarm, stop troubleshooting and book a diagnosis. Most no-heat calls end with one failed part, not a dead furnace.
Stop first if you notice any of these
- Gas smell (rotten eggs): do not touch switches or the thermostat, and do not use a phone inside. Leave the home and call the gas utility or 911 from outside.
- Carbon monoxide alarm: get everyone outside, then call 911.
- Burning or electrical smell, scorch marks, or a breaker that trips again after one reset.
- A boom when the burners light, or a yellow, lazy flame instead of a steady blue one.
A light dusty smell at the first start of the season is normal; it fades within minutes.
How a gas furnace starts, and where it stops
On a call for heat, the small draft inducer motor starts, a pressure switch confirms the vent is clear, the igniter glows or sparks, the gas valve opens and the burners light. The flame sensor must prove the flame within seconds, or the gas closes again. After a short delay the blower sends warm air through the ducts. The furnace stops at the first step that fails, and after a few failed tries many controls lock out.
Safe checks, in order
- Thermostat. Set it to Heat, a few degrees above room temperature, with fresh batteries and no schedule or away mode overriding it. Set the fan to Auto; on On, the blower moves room-temperature air between cycles, which feels cold. See also thermostat not working.
- Filter. A clogged filter makes the furnace overheat. The limit switch shuts the burners off while the blower keeps running, so you get short heat cycles or cool air. Replace it.
- Power. Check the breaker and the furnace service switch, which looks like a light switch. The lower door must be fully seated: it presses a safety switch.
- Gas supply. If the gas stove works, gas is reaching the house. The valve on the furnace’s gas line is open when its handle lines up with the pipe. If the utility shut the gas off, let the utility restore it.
- Status light. Many furnaces blink a code through a small window in the door. Write it down before you cut power, since a reset can clear it, and match it to the chart on the door.
- One reset. Switching the furnace off for a minute and back on can clear a lockout. If it locks out again, leave it off.
- High-efficiency furnaces (white plastic vent pipes): make sure the pipe ends outside are not blocked and the condensate drain tube is not kinked.
Most newer furnaces have electronic ignition and no pilot. On an older one with a standing pilot, relight it only by the instructions on the label, and call if it will not stay lit.
What the symptom usually points to
| What happens | Likely cause | Next step |
|---|---|---|
| Nothing at all | Power, thermostat or wiring, door switch, control fuse | Check power and thermostat |
| Inducer runs, burners never light | Pressure switch not closing, blocked vent or condensate trap, failed igniter | Call |
| Burners light, go out within seconds | Dirty flame sensor, gas pressure, poor ground | Call |
| Blower runs, air stays cold | Fan on On, dirty filter tripping the limit switch, burners not lighting | Check fan and filter |
| Heats a few minutes, shuts off, repeats | Overheating, weak flame signal, oversized furnace | See short cycling |
| Burners run, little air at the vents | Blower motor, capacitor or control (the limit switch then cycles the burners) | Turn off and call |
| Boom, squeal or grinding | Delayed ignition, blower motor or inducer bearings | Turn off; see HVAC strange noises |
The safety controls
A furnace shuts itself down on purpose when something is unsafe: the limit switch on overheating, the pressure switch on poor venting, the flame rollout switch on flames escaping the burner area. These switches are the messenger, not the fault. A tripped rollout switch can point to a blocked flue or a damaged heat exchanger, so do not reset it yourself, and never bypass a safety switch to get heat back.
When to stop troubleshooting
Stop when the checks are done and there is still no heat, or right away if the furnace locks out again after one reset, shows an error code, makes new noises, leaks water or trips a breaker. Anything behind the burner or control panel is technician work. With someone vulnerable to cold at home, emergency HVAC takes calls 24/7.
What a technician checks
A proper diagnosis follows the start-up sequence instead of guessing at parts: thermostat call and wiring, inducer and pressure switch, igniter, gas valve and pressure, flame signal, blower and limit switch. It also covers combustion and venting (flame quality, rollout signs, blocked flues, carbon monoxide), because the goal is a furnace that heats safely. You hear what failed in plain English and get the price before work starts.
An igniter or flame sensor is a routine repair; a cracked heat exchanger, a failed board or blower, or repeated safety trips on an older furnace is when repair or replace becomes a fair question. See furnace repair and heating repair; for a heat pump, heat pump services.
A note for Mountain View and Los Altos homes
Winters here are mild, so furnaces often sit idle until the first cold nights of November; that first start exposes weak igniters, dirty flame sensors and forgotten filters. This guide fits forced-air homes such as many Los Altos ranch houses; many Mountain View Eichlers heat through radiant tubing in the slab instead. Local versions: Mountain View and Los Altos. A fall maintenance visit catches most of these faults early.