Goodman HVAC Repair in Mountain View & Los Altos

Goodman equipment is straightforward, and many repairs are one standard part. The calls that need more care are evaporator coil leaks and control board faults, because both have convincing look-alikes.

  • Same-day appointments
  • Price before work starts
  • 24/7 phone support

Goodman makes affordable central air conditioners, heat pumps, gas furnaces and air handlers with a simple design, and in Mountain View and Los Altos homes many Goodman repairs come down to one standard part: a capacitor, a contactor, a flame sensor or a clogged drain. The three problems that need more careful diagnosis are evaporator coil leaks, control board issues and compressor failures. Each one has a cheaper look-alike, so we prove the cause before we price the repair.

Goodman equipment we work on

  • Central air conditioners: the outdoor unit plus the evaporator coil indoors, on top of the furnace or inside the air handler.
  • Heat pumps that heat and cool from one outdoor unit.
  • Gas furnaces, standard and high-efficiency condensing models.
  • Air handlers, the indoor blower cabinet of a heat pump system, often with electric backup heat.

Evaporator coil leaks: how they show up

The evaporator coil is the indoor half of the cooling system. Warm house air passes over it, the refrigerant inside absorbs the heat, and water condenses on the fins and runs to the drain. When the coil develops a small leak, the system loses refrigerant slowly, and the signs build up over weeks:

  • the house cools more slowly on warm afternoons, and the system runs longer;
  • ice forms on the coil or on the larger, insulated copper line at the outdoor unit;
  • water appears where it should not, as the ice melts faster than the drain can carry it;
  • the system “needed refrigerant” last season and needs it again.

How we confirm a coil leak

A dirty filter, a slow blower or a blocked return can also freeze a coil, so airflow comes first. Then we read the system’s pressures and temperatures, including superheat and subcooling, to see whether it is actually short of refrigerant. If it is, we search for the leak at the coil, the service valves and the line set with an electronic detector and bubble solution. When a leak hides, the system can be isolated and pressure-tested with nitrogen.

What happens next depends on where the leak is:

Where the leak isWhat it usually takes
A brazed joint or a service valve we can reachRepair of that joint or valve
Inside the coil’s tubingA replacement coil matched to the system
Anywhere on an older R-22 systemA repair-versus-replacement comparison before any work

After any leak repair, the system is put under vacuum and charged to the manufacturer’s specification. Refrigerant work is done by EPA-certified technicians. If the coil is replaced, we check whether it is still covered by the manufacturer’s parts warranty first. More on the signs in frozen AC coils and refrigerant leaks.

Control board issues

Goodman furnaces and air handlers have a control board with a status light, and the code chart is usually printed on the panel. A blinking code names the step of the start-up sequence that failed: the pressure switch, the igniter, the flame sensor or a limit switch. Most of the time the named part is the fault, not the board. We test it, along with the board’s power supply, its transformer and its low-voltage fuse, before anyone replaces the board. On Goodman heat pumps, the defrost control in the outdoor unit is another board we check when the outdoor coil stays iced in winter. Our furnace repair page has more on the heating side.

Compressor failures

An outdoor unit that hums, clicks or trips the breaker does not prove a dead compressor. We test the capacitor, the contactor and the compressor windings first; the step-by-step tests are the same ones we describe on our Amana page, since the two brands share a parent company. If the compressor has failed, you get the repair price and the replacement price before anything is done.

What to have ready

  • Photos of the data plate on the outdoor unit and the label inside the furnace or air handler door.
  • The furnace’s blink code, counted before the power is turned off.
  • Whether the system has needed refrigerant before, and roughly when it was installed.

Parts and warranty

Goodman equipment is sold with manufacturer warranties that vary by model, install date and registration. The warranty covers the part, not the labor. When a covered part such as a coil fails, we help you with the claim, and our labor warranty is written on your invoice.

Local notes

In older ranch homes in Mountain View and Los Altos, the furnace and its coil often sit in the garage or the attic, with ducts in the attic or crawlspace. A coil in the attic leaks quietly, and the first sign can be a water stain on the ceiling below when a frozen coil thaws or the drain backs up. Inland afternoons are often hot from July to September, when a slowly leaking coil finally falls behind. A spring AC maintenance visit is the easiest time to catch it. For Mountain View, see also our Goodman repair in Mountain View page.

Frequently asked

How do I know if my Goodman evaporator coil is leaking?

Typical signs are cooling that fades over weeks, longer run times, ice on the indoor coil or the larger copper line, and a system that needed refrigerant before. A dirty filter can cause some of the same signs, so we check airflow before searching for the leak.

Should I repair the leak or replace the coil?

A leak at a reachable joint or valve can often be repaired. A leak inside the coil's tubing usually means a new coil. On an older system, especially one that uses R-22, we also give you the price of replacing the system so you can compare.

My Goodman furnace is blinking a light. What should I do?

Count the blinks before switching anything off and compare them with the chart on the furnace panel. Then call: the code tells us which part of the start-up sequence stopped, which is where testing begins.

Is Goodman related to Amana?

Yes. Goodman and Amana HVAC equipment come from the same parent company and share many designs and parts. Parts are still matched to the model number on your unit.