When a Rheem furnace will not heat, the trouble usually sits in the first minute of its start: the inducer motor, the pressure switch or the ignition control. How far the furnace gets before it stops tells us which one to test.

  • Same-day appointments
  • Price before work starts
  • 24/7 phone support

Rheem HVAC repair in Mountain View and Los Altos covers central air conditioners, heat pumps, air handlers and gas furnaces. The furnace is where three common Rheem faults sit: pressure switch failures, inducer motor problems and ignition control issues. All three happen in the first minute after the thermostat calls for heat, and all three can leave you with a furnace that hums, clicks or blows cold air. Finding the step where the start stops is faster than replacing parts until the heat comes back. You get the price before any work begins. We are an independent service provider, not affiliated with Rheem.

A Rheem furnace start, by ear

You can follow most of the start-up from the hallway:

  1. A steady whir. The inducer motor starts and pulls air through the burners and out the vent.
  2. A soft click. The pressure switch closes once the inducer has proved the vent is drawing.
  3. A glow, then a quiet whoosh. The igniter heats up, the gas valve opens and the burners light.
  4. The blower. After a short delay the main blower starts and warm air reaches the registers.
Where it stopsWhat you noticeWhat we test first
Before step 1Silence; nothing happensThermostat call, power, door switch, fuse, transformer
Between 1 and 2Inducer runs, nothing else; it may retryDraft, vent and condensate drain, inducer, pressure switch tubing
At step 1 itselfRattling, grinding or a rising whineInducer motor bearings and wheel
Between 2 and 3Click, glow, no flameGas supply, gas valve, igniter
Just after 3Flame for a few seconds, then outFlame sensor, ground, flame quality

Count the flashes of the status light before switching anything off; the code chart is usually inside the furnace door, and a power cycle clears the code.

Pressure switch failures: usually the messenger

The pressure switch is a safety device. It lets ignition go ahead only after the inducer has pulled enough draft through the furnace. When it will not close, the switch is rarely the real problem. Common causes are a vent blocked by debris or a nest, a vent pipe without proper slope, a weak inducer, cracked or water-filled tubing, and on high-efficiency condensing furnaces, a clogged condensate trap or drain line. We measure the draft the inducer actually produces and compare it with the rating printed on the switch. That tells us whether to fix the vent, the drain, the inducer or, occasionally, the switch.

Inducer motor problems

The inducer runs every time the furnace starts, so its bearings wear. Warning signs are a rattle or grinding at start-up, a whine that changes pitch, a motor that is slow to come up to speed, and on condensing furnaces, water or rust in the inducer housing from a drain problem. A weak inducer can pass the pressure switch on a cold start and fail once it warms up, which shows up as lockouts that come and go. We check its current draw, bearings, wheel and housing. Noises from other parts of the system are covered in HVAC strange noises.

Ignition control issues

Ignition faults come from the igniter, the gas supply and valve, the flame sensor or the control that runs the sequence, which on most modern furnaces is part of the main control board. A hot surface igniter is brittle and cracks with age; a dirty flame sensor lets the burners light and then shuts them down. After several failed tries the board locks the furnace out for a while. The furnace not heating guide covers the checks you can do safely yourself.

Safety first: if you smell gas, see scorch marks around the burners or your CO alarm sounds, turn the furnace off, leave the house and call the gas company or 911 from outside. For anything else that cannot wait, see emergency HVAC service.

Rheem air conditioners, heat pumps and air handlers

On the cooling side, Rheem equipment gets the same test-first approach: capacitors and contactors under load, coil condition, refrigerant readings and the condensate drain. Heat pumps are paired with an air handler that often has electric heat strips for backup. See AC repair and heat pump services.

What to have ready

  • A photo of the label inside the furnace door and of the data plate on the outdoor unit.
  • The status light flash count, and what you heard before it stopped.
  • Roughly when the system was installed.

Parts and warranty

Igniters, flame sensors and pressure switches are standard parts. Inducer motors and control boards are matched to the model and serial number, and we confirm availability before quoting. Rheem and Ruud equipment comes from the same manufacturer, but the data plate still decides the part. Parts warranties come from the manufacturer, usually depending on the install date and registration; we help with the claim. Our labor warranty is stated on your invoice.

Local notes

In Mountain View and Los Altos, heating runs mostly from November to March, and a furnace that sat idle all summer shows its weak igniter or tired inducer on the first cold night. Many Los Altos ranch homes still heat with forced-air furnaces. A fall maintenance visit catches most of this early; if the heat is already out, see heating repair. Own a Ruud? See our Ruud page. For Mountain View visits, see Rheem service in Mountain View.

Frequently asked

My Rheem furnace hums but never lights. What is wrong?

The hum is usually the inducer motor. If the furnace never moves on to ignition, the pressure switch is not proving draft: a blocked vent or condensate drain, a weak inducer, damaged tubing or the switch itself. Each is tested before a part is replaced.

Can I just replace the pressure switch?

It rarely fixes the problem on its own. The switch usually stays open because the inducer is not creating enough draft, and a new switch sees the same thing. We measure the draft first.

Is it safe to keep resetting my Rheem furnace?

One reset is fine. If it locks out again, leave it off and call. If you smell gas, leave the house and call the gas company or 911 from outside.